Skip to content
Description
Technical data
- Voltage supply
-
- Consumption w/o load
-
- ≤100 mA (per interface SSI)
- ≤250 mA (per interface bus)
- Initializing time
-
- Interface
-
- SSI
- Profibus-DPV0
- CANopen®
- DeviceNet
- Function
-
- Transmission rate
-
- 9.6 … 12000 kBaud (Profibus)
- 10 … 1000 kBaud (CANopen®)
- 125 … 500 kBaud (DeviceNet)
- Profile conformity
-
- Profibus-DPV0
- CANopen® CiA DSP 406 V 3.0
- Device Profile Encoder V 1.0
- Device adress
-
- Rotary switches in bus cover
- Steps per revolution
-
- Number of revolutions
-
- Additional outputs
-
- Square-wave TTL (RS422)
- Square-wave HTL
- Sensing method
-
- Code
-
- Code sequence
-
- Inputs
-
- Incremental output
-
- 2048 pulses per revolution
- Interference immunity
-
- Emitted interference
-
- Programmable parameters
-
- Depending on the selected absolute interface
- Diagnostic function
-
- Position or parameter error
- Status indicator
-
- DUO-LED integrated in bus cover
- Approval
-
- Size (flange)
-
- Shaft type
-
- ø38…70 mm (through hollow shaft)
- Protection EN 60529
-
- Operating speed
-
- Operating torque typ.
-
- Rotor moment of inertia
-
- Admitted shaft load
-
- ≤350 N axial
- ≤500 N radial
- Material
-
- Housing: aluminium
- Shaft: stainless steel
- Corrosion protection
-
- IEC 60068-2-52 Salt mist
- for ambient conditions C4 according to ISO 12944-2
- Operating temperature
-
- Resistance
-
- IEC 60068-2-6
- Vibration 10 g, 10-2000 Hz
- IEC 60068-2-27
- Shock 200 g, 6 ms
- Explosion protection
-
- II 3 G Ex ec IIC T4 Gc (gas)
- II 3 D Ex tc IIIB T135°C Dc (dust)
- (only with option ATEX)
- Weight approx.
-
- 5 – 6.4 kg (depending on version)
- Connection
-
- Bus cover
- Connecting terminal (SSI/incremental)