GAM900

Request for quote

In stock

Description

Technical data
Technical data – electrical ratings

Voltage supply
  • 10…30 VDC
Reverse polarity protection
  • Yes
Consumption w/o load
  • ≤200 mA (24 VDC)
Initializing time
  • ≤ 2000 ms after power on
Interface
  • CANopen®
  • Analog 4…20 mA (0…10 V optional)
Frequency bands
  • 6 (configurable)
Measuring range
  • ±2 g
Resolution
  • < 4 mg
Accuracy 3σ
  • = 35 mg (in the range of ±1000 mg)
  • = 10 mg (in the range of ±250 mg)
  • (with band pass filtering, up to -1dB)
Interference immunity
  • DIN EN 61000-6-2
  • DIN EN 61326-3-1
Emitted interference
  • EN 61000-6-4
Status indicator
  • DUO-LED integrated in housing
Technical data – mechanical design

Dimensions W x H x L
  • 55 x 30 x 90 mm
Protection EN 60529
  • IP 55
Material
  • Aluminium
Operating temperature
  • -40…+75 °C
Resistance
  • DIN EN 60068-2-6 Vibration 20 g, 60-2000 Hz
  • DIN EN 60068-2-27 Shock 100 g, 6 ms
Weight approx.
  • 250 g
Connection
  • Connector M12

Request for quote