Description
Technical data
Performance characteristics
- Measuring principle
-
- Electromagnetic flow measurement
- Max. flow velocity
-
- 10 m/s
- Media characteristics
-
- ≥ 50 µS/cm
- Measuring range, flow
-
- 1.9 … 1200 l/min
- 0.4 … 10 m/s
- Measuring range, temperature
-
- -10 … 100 °C
- Min. measuring span
-
- 0.2 … 0.4 m/s
- Hysteresis
-
- 3 % o. r.
- Max. measuring error
-
- ± 1.0 % o. r.
- ± 2 °C
- Max. turndown ratio
-
- 1 : 1000
- Temperature drift (by ambient)
-
- 0.03 % FSR/10 K
- Repeatability
-
- ≤ 0.25 % o. r.
- Step response time
-
- ≤ 400 ms
- Sampling interval
-
- ≤ 200 ms
- Damping
-
- 0.2 … 1000 s
Ambient conditions
- Degree of protection (EN 60529)
-
- IP 67
Compliance and approvals
- EMC
-
- IEC 61326-1
- EN 61326-1
- Pressure directive
-
- PED