Skip to content
Description
Technical data
- Shaft insulation
-
- Transmission length
-
- ≤350 m at 100 kHz (HTL-P)
- ≤550 m at 100 kHz (TTL)
- Interference immunity
-
- Emitted interference
-
- Approval
-
- Voltage supply
-
- Consumption w/o load
-
- Pulses per revolution
-
- Phase shift
-
- Duty cycle
-
- Reference signal
-
- Output frequency
-
- ≤120 kHz
- ≤300 kHz (on request)
- Output signals
-
- K1, K2, K0 + inverted
- Error output (option EMS)
- Output stages
-
- HTL-P (power linedriver)
- TTL/RS422
- Sensing method
-
- Switching accuracy
-
- ± 4 % (Δn = 2 rpm/s);
- 20 % (Δn = 1500 rpm/s)
- Switching deviation
-
- Switching hysteresis
-
- Switching outputs
-
- Output switching capacity
-
- ≤6 A / 230 VAC
- ≤1 A / 125 VDC
- (EAC: <50 VAC / 75 VDC)
- Minimum switching current
-
- Size (flange)
-
- Shaft type
-
- ø16…20 mm (blind hollow shaft)
- ø17 mm (cone shaft 1:10)
- Admitted shaft load
-
- ≤450 N axial
- ≤600 N radial
- Protection EN 60529
-
- Speed (n)
-
- Range of switching speed (ns)
-
- 850…4500 rpm (Δn = 2 rpm/s)
- Operating torque typ.
-
- Rotor moment of inertia
-
- Material
-
- Housing: aluminium die-cast
- Shaft: stainless steel
- Operating temperature
-
- -40…+100 °C
- -25…+100 °C (>3072 pulses)
- -50…+100 °C (optional)
- Resistance
-
- IEC 60068-2-6
- Vibration 5 g, 10-2000 Hz
- IEC 60068-2-27
- Shock 50 g, 11 ms
- Corrosion protection
-
- IEC 60068-2-52 Salt mist
- for ambient conditions CX (C5-M) according to ISO 12944-2
- Connection
-
- 2x terminal box
- 3x terminal box (with option M)
- Weight approx.
-
- 2.2 kg
- 2.4 kg (with option M)