DAB10-AU

Request for quote

In stock

Description

Technical data
General data

Output signal
  • ± 10 VDC
  • IO-Link
Non-linearity
  • < 0.01 %
Repeatability
  • < 0.01 %
Temperature effect zero
  • < 0.01 % / 10K
Mechanical data

Material housing
  • Aluminium, 6060, chem. passivated
Electrical connection on sensor side
  • M8, 4 pin, female
Electrical connection on control side
  • M12, 5 pin, male
Environmental conditions

Operating temperature range
  • -40 … 85 °C
Storage temperature range
  • -40 … 85 °C
Protection class EN 60529, ISO20653
  • IP 65
Vibration IEC 60068-2-6
  • 10 … 57 Hz: 1.5 mm p-p, 58 … 2000 Hz: 10 g
Random IEC 60068-2-64
  • 20 … 1000 Hz: 0.1 g²/Hz
Shock IEC 60068-2-27
  • 50 g / 11 ms, 100 g / 6 ms
Electrical data bridge

Bridge resistance
  • ≥ 350 Ω
Signal area
  • ± 3.8 mV/V
Power supply
  • 2.5 VDC
Electrical data

Supply voltage
  • 18 … 30 VDC
Current consumption
  • < 40 mA
Resolution ADC
  • 24 bit
Sampling rate input
  • 8 kS/s
Resolution DAC
  • 14 bit
Sampling rate output analog
  • 8 kS/s
Cut-off frequency (3 db)
  • 1 kHz
SNR @1.0 mV/V
  • > 75 dB
Short circuit protection
  • Yes
Reverse polarity protection
  • Yes
Max. Output range
  • ± 11 VDC
Output current
  • < 100 mA
IO-Link interface

IO-Link version
  • 1.1
IO-Link port type
  • Class A
Baud rate
  • 230,4 kbaud (COM3)
Process data length
  • 32 bit
Cycle time
  • ≥ 1 ms
SIO-mode
  • Yes
Process data (cyclic)
  • Process Value
  • Scale exponent
  • SSC 1
  • SSC 2
  • Quality
  • Alarm
IO-Link features

Parameterizable
  • Process input
  • Unit (N, kg, µm/m) selectable
  • Teach-in Offset/ Tare
  • Correlation to known force
  • Analog output signal
  • Output range analog signal
  • Alarm state analog signal
  • Functions I/O’s selectable
Additional functions
  • Low pass filter
  • Peak value memory
  • Sample and hold
  • Two digital switching points (SSC)
  • Remote operation
Additional data
  • Diagnostic data
  • Error detection
Compliance and approvals

Conformity
  • CE
  • UL

Request for quote