Image Name Description Category
GCA12 – CANopen®Technical data Technical data – electrical ratings Voltage supply 10…30 VDC Consumption typ. 25 mA…, ,
GCA12 – analogTechnical data Technical data – electrical ratings Voltage supply 8…30 VDC 12…30 VDC Reverse polarity…, ,
optoPulse EIL580P-SCTechnical data Technical data – electrical ratings Voltage supply 4.75…30 VDC Reverse polarity protection Yes…, , , , ,
GCA3-PT – SSI up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 4.5…30 VDC Reverse polarity protection Yes…, ,
GCA3-PT – CANopen® up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 10…30 VDC Reverse polarity protection Yes…, ,
GCA3-PT – analog up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…30 VDC 14…30 VDC Consumption typ.…, ,
GCA3-PM – SAE J1939 up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
GCA3-PM – CANopen® up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
GCA3-PM – analog up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…30 VDC 12…30 VDC Reverse polarity…, ,
GCA12 – SAE J1939Technical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
GCA8 – CANopen®Technical data Technical data – electrical ratings Voltage supply 10…30 VDC Consumption typ. 25 mA…, ,
GCA8 – analogTechnical data Technical data – electrical ratings Voltage supply 8…30 VDC 12…30 VDC Reverse polarity…, ,
GCA5 – SAE J1939 up to 7.8 mTechnical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
GCA5 – SAE J1939 to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
GCA5 – CANopen® up to 7.8 mTechnical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
GCA5 – CANopen® up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
GCA5 – analog up to 7.8 mTechnical data Technical data – electrical ratings Voltage supply 8…30 VDC 12…30 VDC Reverse polarity…, ,
GCA5 – analog up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…30 VDC 12…30 VDC Reverse polarity…, ,
Cable transducer GCI/GCA4 (2 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
Cable transducer GCI/GCA2 (2.4 m)Technical data Technical data Material Housing: Polyester Cable transducer: stainless steel cable coated with polyamide…, ,
GCA12 – CANopen®Technical data Technical data – electrical ratings Voltage supply 10…30 VDC Consumption typ. 25 mA…, ,
Cable transducer GCI/GCA15 (7.5 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
GCA12 – analogTechnical data Technical data – electrical ratings Voltage supply 8…30 VDC 12…30 VDC Reverse polarity…, ,
Cable transducer GCI/GCA15 (5 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
Cable transducer GCI/GCA15 (15 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
Cable transducer GCI/GCA15 (10 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
GCA3-PT – SSI up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 4.5…30 VDC Reverse polarity protection Yes…, ,
GCA3-PT – CANopen® up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 10…30 VDC Reverse polarity protection Yes…, ,
GCA8 – SAE J1939Technical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
GCA3-PT – analog up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…30 VDC 14…30 VDC Consumption typ.…, ,
GCA3-PM – SAE J1939 up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
Cable transducer GCI/GCA50 (50 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
GCA3-PM – CANopen® up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
GCA3-PM – analog up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…30 VDC 12…30 VDC Reverse polarity…, ,
Cable transducer GCI/GCA50 (40 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
GCA12 – SAE J1939Technical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
GCA8 – CANopen®Technical data Technical data – electrical ratings Voltage supply 10…30 VDC Consumption typ. 25 mA…, ,
Cable transducer GCI/GCA50 (30 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
GCA5 – SAE J1939 up to 7.8 mTechnical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
Cable transducer GCI/GCA4 (3 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
GCA8 – analogTechnical data Technical data – electrical ratings Voltage supply 8…30 VDC 12…30 VDC Reverse polarity…, ,
GCA5 – SAE J1939 to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
GCA5 – CANopen® up to 7.8 mTechnical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
GCA5 – CANopen® up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
GCA5 – analog up to 7.8 mTechnical data Technical data – electrical ratings Voltage supply 8…30 VDC 12…30 VDC Reverse polarity…, ,
GCA5 – analog up to 4.7 mTechnical data Technical data – electrical ratings Voltage supply 8…30 VDC 12…30 VDC Reverse polarity…, ,
Cable transducer GCI/GCA4 (2 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
Cable transducer GCI/GCA2 (2.4 m)Technical data Technical data Material Housing: Polyester Cable transducer: stainless steel cable coated with polyamide…, ,
Cable transducer GCI/GCA15 (7.5 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
Cable transducer GCI/GCA15 (5 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
Cable transducer GCI/GCA15 (10 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
Cable transducer GCI/GCA15 (15 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
GCA8 – SAE J1939Technical data Technical data – electrical ratings Voltage supply 8…36 VDC Reverse polarity protection Yes…, ,
Cable transducer GCI/GCA50 (50 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
Cable transducer GCI/GCA50 (40 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
Cable transducer GCI/GCA50 (30 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
Cable transducer GCI/GCA4 (3 m)Technical data Technical data Material Housing: aluminium Cable transducer: stainless steel cable coated with polyamide…, ,
UNAM 50N3721/S14Technical data General data Scanning range Sd 350 … 2500 mm Scanning range far limit…,
UNDK 10P8914/S35ATechnical data General data Scanning range Sd 10 … 200 mm Scanning range far limit…,
UNDK 20P7914/S35ATechnical data General data Scanning range Sd 10 … 200 mm Scanning range far limit…,
UNDK 20P7912/S35ATechnical data General data Scanning range Sd 40 … 400 mm Scanning range far limit…,
UNDK 30N3703/S14Technical data General data Scanning range Sd 100 … 1000 mm Scanning range far limit…,
UNDK 30P1712/S14Technical data General data Scanning range Sd 60 … 400 mm Scanning range far limit…,
UNDK 30P3703/S14Technical data General data Scanning range Sd 100 … 1000 mm Scanning range far limit…,
UZAM 50P6121/S14Technical data General data Special type 2 point proximity switch Scanning range Sd 350 ……,