IWRR 18I97T4/S14

Request for quote

Description

Technical data
General data

Mounting type
  • Quasi-flush
Special type
  • Outdoor design
  • Washdown design
Measuring distance Sd
  • 0 … 7 mm
Resolution
  • < 0.005 mm (stat.)
  • < 0.01 mm (dynam.)
Repeat accuracy
  • 0.015 mm
Linearity error
  • ± 350 µm
Temperature drift
  • ± 10 % (Full Scale)
Approvals/certificates
  • Ecolab
Electrical data

Response time (factory characteristic)
  • < 2 ms
Voltage supply range +Vs
  • 15 … 30 VDC
Current consumption max. (no load)
  • 40 mA
Output circuit
  • Analog 4 … 20 mA
Load resistance +Vs min.
  • < 330 Ohm
Load resistance +Vs max.
  • < 1000 Ohm
Short circuit protection
  • Yes
Reverse polarity protection
  • Yes
Mechanical data

Design
  • Cylindrical threaded
Material (sensing face)
  • LCP
Housing material
  • Stainless steel 1.4404 (V4A)
Dimension
  • 18 mm
Housing length
  • 60 mm
Connection types
  • Connector M12
Tightening torque max.
  • 55 Nm (Front: 38 Nm)
Ambient conditions

Operating temperature
  • -40 … +70 °C
Cleaning temperature
  • 70 … +85 °C (30 min/day)
Protection class
  • IP 68/69K & proTect+
Vibration resistance
  • EN 61373: 2010 (category 3), 5h per axis (14.4 gRMS, 10-500 Hz, EN 60068-2-64)
Shock resistance
  • EN 61373: 2010 (category 3), 10 bumps per axis (100 g, 6 ms, EN 60068-2-27)

Request for quote