EExOG 9

Request for quote

Description

Technical data
Technical data – electrical ratings

Voltage supply
  • 9…30 VDC
  • 5 VDC ±5 %
  • 9…26 VDC
Consumption w/o load
  • ≤100 mA
Pulses per revolution
  • 120 … 5000
Phase shift
  • 90 ° ±20°
Duty cycle
  • 40…60 %
Reference signal
  • Zero pulse, width 90°
Sensing method
  • Optical
Output frequency
  • ≤120 kHz (pulses ≤1250)
  • ≤250 kHz (pulses >1250)
Output signals
  • K1, K2, K0 + inverted
Output stages
  • HTL
  • TTL/RS422
Interference immunity
  • EN 61000-6-2
Emitted interference
  • EN 61000-6-3
Approval
  • CE
  • ATEX
  • IECEx
Technical data – mechanical design

Size (flange)
  • ø115 mm
Shaft type
  • ø11 mm solid shaft
Admitted shaft load
  • ≤200 N axial
  • ≤350 N radial
Flange
  • EURO flange B10
Protection EN 60529
  • IP 56
Operating speed
  • ≤6000 rpm (T5, mechanical)
  • ≤4500 rpm (T6, mechanical)
Operating torque typ.
  • 4 Ncm
Rotor moment of inertia
  • 290 gcm²
Material
  • Housing: aluminium die-cast
  • Shaft: stainless steel
Ambient temperature
  • -20…+55 °C
  • (Extended temperature range on request)
Resistance
  • IEC 60068-2-6
  • Vibration 10 g, 50-2000 Hz
  • IEC 60068-2-27
  • Shock 100 g, 6 ms
Corrosion protection
  • IEC 60068-2-52 Salt mist
  • for ambient conditions C4 according to ISO 12944-2
Explosion protection
  • II 2 G Ex db eb IIC T5/T6 Gb
  • Ex db eb IIC T5/T6 Gb
Connection
  • Terminal box
Weight approx.
  • 3.5 kg

Request for quote