Skip to content
Description
Technical data
- Process temperature
-
- 115 … 135 °C , < 1 h
- -40 … 115 °C , permanent
- Min. output span
-
- Pt100 accuracy class (EN 60751)
-
- B (± 0.3 °C at 0 °C)
- ± (0.3 + 0.005 × t)°C
- A (± 0.15 °C at 0 °C)
- ± (0.15 + 0.002 × t)°C
- 1/3 B (± 0.1 °C at 0 °C)
- ± 1/3 × (0.3 + 0.005 × t)°C
- 1/6 B (± 0.05 °C at 0 °C)
- ± 1/6 × (0.3 + 0.005 × t)°C
- Max. conversion error
-
- Max. output error
-
- Temperature drift (by ambient)
-
- < 0.003 % FSR/°C , typ.
- < 0.01 % FSR/°C , max.
- Thermal response time, T90
-
- ≤ 6.5 s , 20 mm
- ≤ 6.7 s , 50 mm
- ≤ 66.0 s , front-flush
- Thermal response time, T50
-
- ≤ 2.5 s , 20 mm.
- ≤ 2.7 s , 50 mm
- ≤ 9.0 s , front-flush
- Sampling interval
-
- Immersion length
-
- 0 mm , front-flush
- 20 mm
- 50 mm
- Sensor tube material
-
- Wetted parts material
-
- Surface roughness wetted parts
-
- Degree of protection (EN 60529)
-
- IP67
- IP69K , with appropriate cable
- Humidity
-
- Vibration (sinusoidal) (EN 60068-2-6)
-
- 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
- Without transmitter
-
- With transmitter
-
- Shunt resistance
-
- Rs ≤ (Vs – 8 V)/0.023 A
- Rs ≤ 680 Ohm, Vs = 24 V DC
- EMC
-
- EN 61000-6-2
- EN 61000-6-3
- EN 61326-1
- Hygiene
-
- FDA (21 CFR 177.2415)
- 3-A (74-07)