Skip to content
Description
Technical data
- Process temperature
-
- Refer to section “Operating conditions”
- Pt100 accuracy class (EN 60751)
-
- B (± 0.3 °C at 0 °C)
- ± (0.3 + 0.005 × t)°C
- A (± 0.15 °C at 0 °C)
- ± (0.15 + 0.002 × t)°C
- 1/3 B (± 0.1 °C at 0 °C)
- ± 1/3 × (0.3 + 0.005 × t)°C
- 1/6 B (± 0.05 °C at 0 °C)
- ± 1/6 × (0.3 + 0.005 × t)°C
- Thermal response time, T50
-
- < 1.5 s , Ø4 mm
- < 6.1 s , Ø6 mm
- < 7.6 s , Ø8 mm
- Process pressure
-
- Refer to section “Operating conditions”
- Sensor length
-
- Sensor tube material
-
- Surface roughness wetted parts
-
- Degree of protection (EN 60529)
-
- IP67
- IP69K , with appropriate cable
- Humidity
-
- Vibration (sinusoidal) (EN 60068-2-6)
-
- 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
- Without transmitter
-
- 1 x Pt100, 2-wire
- 1 x Pt100, 4-wire
- 2 x Pt100, 2-wire
- With transmitter
-
- 4 … 20 mA , 2-wire
- 4 … 20 mA , 2-wire + HART®
- Cable
-
- M16 plastic, cable dia. 5 … 10 mm
- M16 stainless steel, cable dia. 5 … 9 mm
- M20 plastic, cable dia. 8 … 13 mm
- M20 stainless steel, cable dia. 9 … 13 mm
- EMC
-
- EN 61000-6-2
- EN 61000-6-3
- EN 61326-1
- Hygiene
-
- EHEDG EL Class I
- 3-A (74-07)
- Explosion protection
-
- ATEX II 1 G Ex ia IIC T6…T4
- IECEx Ex ia IIC T6…T4
- ATEX II 3 G Ex ec IIC T5…T4
- Ex ia Simple apparatus, gas and dust