HMG10-T – Incremental

Ajánlatkérés

Leírás

Technical data
Technical data – electrical ratings

Voltage supply
  • 4.75…30 VDC
Short-circuit proof
  • Yes
Consumption w/o load
  • ≤100 mA
Initializing time
  • ≤ 500 ms after power on
Pulses per revolution
  • 1 … 131072
Phase shift
  • 90 ° ±20°
Duty cycle
  • 40…60 %
Reference signal
  • Zero pulse, width 90°
Sensing method
  • Magnetic
Output signals
  • A+, B+, R+, A-, B-, R-
  • Error output nE+, nE-
Output stages
  • TTL/HTL (Vin = Vout)
Programming interface
  • RS485 (≤600 m)
Programmable parameters
  • Pulse number
  • Switch-off and switch-on speeds
  • Switching delay time
Diagnostic function
  • Function control
Status indicator
  • 4 LEDs in device back side
Interference immunity
  • EN 61000-6-2
Emitted interference
  • EN 61000-6-3
Approval
  • CE
  • UL approval / E217823
Technical data – electrical ratings (speed switch)

Switching accuracy
  • ± 2 % (or 1 Digit)
Switching outputs
  • 1 output (Open collector)
Output switching capacity
  • 30 VDC; ≤100 mA
Switching hysteresis
  • 10 … 100 % adjustable
Switching delay time
  • ≤20 ms
Technical data – mechanical design

Size (flange)
  • ø105 mm
Shaft type
  • ø16…20 mm (through hollow shaft)
Admitted shaft load
  • ≤450 N axial
  • ≤650 N radial
Flange
  • Support plate for torque arm, 360° freely positionable
Protection EN 60529
  • IP 66 / IP 67
Operating speed
  • ≤12000 rpm
Range of switching speed
  • ns (off) = ±2…12000 rpm, factory setting 6000 rpm
Operating torque typ.
  • 10 Ncm
Rotor moment of inertia
  • 950 gcm²
Material
  • Housing: aluminium alloy
  • Shaft: stainless steel
Operating temperature
  • -40…+95 °C
Relative humidity
  • 95 % non-condensing
Resistance
  • IEC 60068-2-6
  • Vibration 30 g, 10-2000 Hz
  • IEC 60068-2-27
  • Shock 400 g, 1 ms
Corrosion protection
  • IEC 60068-2-52 Salt mist
  • for ambient conditions CX (C5-M) according to ISO 12944-2
Connection
  • Terminal box
  • Flange connector M23
Weight approx.
  • 1.6 kg

Ajánlatkérés